CVE-2017-12718: Smiths-medical medfusion 4000 wireless syringe infusion pump classic buffer overflow vulnerability

SSmiths Medical · Medfusion 4000 Wireless Syringe Infusion Pump

A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.

8.1 CVSS 3.0 High EPSS 13% · top 3.8% CWE-120 · Classic buffer overflowCWE-119 · Memory buffer overflow
8.1CVSS 3.0 base score, v2 6.8
13%EPSS exploitation probability, 30 days
NoNot in CISA KEV
1Affected product versions listed by NVD
8References
17 Jun 2026Last modified by NVD

Description

A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.

CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected products

1 vulnerable configurations from NVD's CPE data, grouped by vendor and product.

References

LinkTags
http://www.securityfocus.com/bid/100665 Third Party AdvisoryVDB Entry
http://www.securityfocus.com/bid/101252 Third Party AdvisoryVDB Entry
https://ics-cert.us-cert.gov/advisories/ICSMA-17-250-02A Third Party AdvisoryUS Government Resource
https://www.exploit-db.com/exploits/43776/ Third Party AdvisoryVDB Entry
http://www.securityfocus.com/bid/100665 Third Party AdvisoryVDB Entry
http://www.securityfocus.com/bid/101252 Third Party AdvisoryVDB Entry
https://ics-cert.us-cert.gov/advisories/ICSMA-17-250-02A Third Party AdvisoryUS Government Resource
https://www.exploit-db.com/exploits/43776/ Third Party AdvisoryVDB Entry

Track CVE-2017-12718 inside VULONE

Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.

Start free Open in platform

Related vulnerabilities

Same products first, then exploited flaws of the same weakness class.

8.1CVE-2017-12720Smiths-medical medfusion 4000 wireless syringe infusion pump missing authentication for critical function vulnerabilityAn Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP s…EPSS 1.9%8.1CVE-2017-12724Smiths-medical medfusion 4000 wireless syringe infusion pump hard-coded credentials vulnerabilityA Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The …EPSS 1.3%7.3CVE-2017-12726Smiths-medical medfusion 4000 wireless syringe infusion pump hard-coded credentials vulnerabilityA Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet …EPSS 1.1%5.9CVE-2017-12721Smiths-medical medfusion 4000 wireless syringe infusion pump improper certificate validation vulnerabilityAn Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. T…EPSS 0.67%5.6CVE-2017-12725Smiths-medical medfusion 4000 wireless syringe infusion pump hard-coded credentials vulnerabilityA Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The …EPSS 0.83%5.3CVE-2017-12722Smiths-medical medfusion 4000 wireless syringe infusion pump out-of-bounds read vulnerabilityAn Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party …EPSS 2.4%3.7CVE-2017-12723Smiths-medical medfusion 4000 wireless syringe infusion pump information exposure vulnerabilityA Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The…EPSS 0.98%5.5CVE-2025-43520Apple OS kernel memory corruption via malicious appA memory corruption flaw (classic buffer overflow) in Apple's kernel was fixed across iOS, iPadOS, macOS, tvOS, visionOS and watchOS. A malicious app…KEVEPSS 0.43%analysed

Source: NIST National Vulnerability Database (record CVE-2017-12718), CISA KEV, FIRST EPSS (scores of 2026-09-27). This page is refreshed as NVD updates the record.