← Vulnerability feed

Vulnerability record · CVE-2013-2796 · published 9 August 2013

CVE-2013-2796: Schneider-electric citectscada permissions and access controls vulnerability

Schneider Electric · Citectscada

Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.

6.9 CVSS 2.0 Medium EPSS 0.73% · top 47.8% CWE-264 · Permissions and access controls
6.9CVSS 2.0 base score
0.73%EPSS exploitation probability, 30 days
NoNot in CISA KEV
3Affected product versions listed by NVD
4References
16 Jun 2026Last modified by NVD

Description

Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.

AV:L/AC:M/Au:N/C:C/I:C/A:C

Affected products

3 vulnerable configurations from NVD's CPE data, grouped by vendor and product.

References

Track CVE-2013-2796 inside VULONE

Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.

Start free Open in platform

Related vulnerabilities

Same products first, then exploited flaws of the same weakness class.

10.0CVE-2013-3075Mitsubishi-automation mitsubishi mx component memory buffer overflow vulnerabilityMultiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1,…EPSS 11%7.8CVE-2019-10981Schneider-electric citectscada insufficiently protected credentials vulnerabilityIn Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access t…EPSS 0.38%7.8CVE-2013-2824Schneider-electric citectscada vulnerabilitySchneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare Pow…EPSS 1.8%7.2CVE-2011-3330Schneider-electric monitor pro memory buffer overflow vulnerabilityBuffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect …EPSS 1.3%4.6CVE-2011-5163Mitsubishi-automation mx4 scada memory buffer overflow vulnerabilityBuffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA b…EPSS 0.47%5.1CVE-2015-3246libuser userhelper direct /etc/passwd write race conditionlibuser before 0.56.13-8 and 0.60 before 0.60-7, as used by the userhelper program in the usermode package, modifies /etc/passwd directly instead of …KEVEPSS 8.8%analysed6.6CVE-2015-1769Windows Mount Manager symlink mishandling allows local privilege escalationThe Windows Mount Manager mishandles symbolic links, allowing a crafted USB device to trigger arbitrary code execution. Because the flaw is in a core…KEVEPSS 4.1%analysed7.8CVE-2016-3643SolarWinds Virtualization Manager sudo misconfiguration privilege escalationSolarWinds Virtualization Manager 6.3.1 and earlier ship with a misconfigured sudo policy that lets a local user run privileged commands, as shown by…KEVEPSS 3.7%analysed

Source: NIST National Vulnerability Database (record CVE-2013-2796), CISA KEV, FIRST EPSS (scores of 2026-09-26). This page is refreshed as NVD updates the record.