Vulnerability record · CVE-2026-88878 · published 10 September 2026
CVE-2026-88878: Traefik allocation without limits vulnerability
Traefik · Traefik
Traefik is an HTTP reverse proxy and load balancer. In versions >= v2.8.2 through <= v2.11.55 and >= v3.0.0 through <= v3.7.11, the entryPoints.<name>.transport.respondingTimeouts settings — notably readTimeout, which is enabled by default at 60s — are not applied to the HTTP/3 request path. readTimeout is enforced as a deadline on the underlying TCP connection, which cannot be applied to a QUIC stream, and Traefik's HTTP/3 server is constructed without any timeout. As a result, on entry points with HTTP/3 enabled, an unauthenticated remote client that trickles request body bytes can hold a request open indefinitely and, with it, one upstream connection per request, exhausting bounded backend connection pools and causing denial of service. The issue was introduced in v2.8.2 when a quic-go API change removed the embedded http.Server that carried these timeouts. Fixed in v2.11.56 and v3.7.12.
Description
Traefik is an HTTP reverse proxy and load balancer. In versions >= v2.8.2 through <= v2.11.55 and >= v3.0.0 through <= v3.7.11, the entryPoints.<name>.transport.respondingTimeouts settings — notably readTimeout, which is enabled by default at 60s — are not applied to the HTTP/3 request path. readTimeout is enforced as a deadline on the underlying TCP connection, which cannot be applied to a QUIC stream, and Traefik's HTTP/3 server is constructed without any timeout. As a result, on entry points with HTTP/3 enabled, an unauthenticated remote client that trickles request body bytes can hold a request open indefinitely and, with it, one upstream connection per request, exhausting bounded backend connection pools and causing denial of service. The issue was introduced in v2.8.2 when a quic-go API change removed the embedded http.Server that carried these timeouts. Fixed in v2.11.56 and v3.7.12.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:
Affected products
1 vulnerable configurations from NVD's CPE data, grouped by vendor and product.
References
| Link | Tags |
|---|---|
| https://github.com/traefik/traefik/security/advisories/GHSA-7ghq-v6jf-g56c | PatchVendor Advisory |
| https://www.vulncheck.com/advisories/traefik-2.8.2-through-3.6-http-3-timeout-bypass | Third Party Advisory |
Track CVE-2026-88878 inside VULONE
Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.
Related vulnerabilities
Same products first, then exploited flaws of the same weakness class.
Source: NIST National Vulnerability Database (record CVE-2026-88878), CISA KEV, FIRST EPSS (scores of 2026-10-03). This page is refreshed as NVD updates the record.