← Vulnerability feed

Vulnerability record · CVE-2026-80947 · published 11 September 2026

CVE-2026-80947: In the Linux kernel, the following vulnerability has been resolved: wifi: rtl8xxxu: fix use-after-free from r…

In the Linux kernel, the following vulnerability has been resolved: wifi: rtl8xxxu: fix use-after-free from rx_urb_wq on stop rtl8xxxu arms rx_urb_wq from the RX completion path: rtl8xxxu_rx_complete() hands the URB to rtl8xxxu_queue_rx_urb(), which queues it on rx_urb_pending_list and, once the list grows past RTL8XXXU_RX_URB_PENDING_WATER, schedules rx_urb_wq. The worker rtl8xxxu_rx_urb_work() drains rx_urb_pending_list, recovers priv through container_of, and resubmits each URB through rtl8xxxu_submit_rx_urb(), which anchors it on rx_anchor and dereferences priv->udev. rtl8xxxu_stop() cancels the sibling work items (c2hcmd_work, ra_watchdog, update_beacon_work) but never cancels rx_urb_wq, so a worker armed during the last burst of RX traffic can run rtl8xxxu_rx_urb_work() after rtl8xxxu_disconnect() has called ieee80211_free_hw(), which frees priv, producing a use-after-free. The window opens under active RX traffic (pending count above the watermark) followed by a disconnect. There are two teardown races to close: * rtl8xxxu_queue_rx_urb() decided whether to enqueue under rx_urb_lock but called schedule_work() after dropping the lock. A completion that observed shutdown == false and released the lock could then call schedule_work() after rtl8xxxu_stop() had set shutdown and cancel_work_sync() had already returned, arming the worker to run after the teardown. Move schedule_work() under the same !shutdown branch so the arming decision is atomic with the shutdown check. * rtl8xxxu_rx_urb_work() anchors every URB it drained back onto rx_anchor through rtl8xxxu_submit_rx_urb(). A worker still running when usb_kill_anchored_urbs(&priv->rx_anchor) returned would submit a URB that escaped the kill. In rtl8xxxu_stop(), call cancel_work_sync(&priv->rx_urb_wq) before the kill so the worker is drained first. After priv->shutdown is set under rx_urb_lock, completions can no longer queue rx_urb_wq. cancel_work_sync() then drains the last queued or running worker, and the following usb_kill_anchored_urbs() kills the URBs it may have submitted. rtl8xxxu_disconnect() is covered because ieee80211_unregister_hw() guarantees .stop() runs for a live interface before ieee80211_free_hw() frees priv. The probe error path needs no cancel: rx_urb_wq is INIT_WORK()'d there but cannot have been scheduled, since no URB is submitted before ieee80211_register_hw() succeeds. This bug was found by static analysis.

7.8 CVSS 3.1 High EPSS 0.17% · top 94.3% Received
7.8CVSS 3.1 base score
0.17%EPSS exploitation probability, 30 days
NoNot in CISA KEV
0Affected product versions listed by NVD
4References
13 Sep 2026Last modified by NVD

Description

In the Linux kernel, the following vulnerability has been resolved: wifi: rtl8xxxu: fix use-after-free from rx_urb_wq on stop rtl8xxxu arms rx_urb_wq from the RX completion path: rtl8xxxu_rx_complete() hands the URB to rtl8xxxu_queue_rx_urb(), which queues it on rx_urb_pending_list and, once the list grows past RTL8XXXU_RX_URB_PENDING_WATER, schedules rx_urb_wq. The worker rtl8xxxu_rx_urb_work() drains rx_urb_pending_list, recovers priv through container_of, and resubmits each URB through rtl8xxxu_submit_rx_urb(), which anchors it on rx_anchor and dereferences priv->udev. rtl8xxxu_stop() cancels the sibling work items (c2hcmd_work, ra_watchdog, update_beacon_work) but never cancels rx_urb_wq, so a worker armed during the last burst of RX traffic can run rtl8xxxu_rx_urb_work() after rtl8xxxu_disconnect() has called ieee80211_free_hw(), which frees priv, producing a use-after-free. The window opens under active RX traffic (pending count above the watermark) followed by a disconnect. There are two teardown races to close: * rtl8xxxu_queue_rx_urb() decided whether to enqueue under rx_urb_lock but called schedule_work() after dropping the lock. A completion that observed shutdown == false and released the lock could then call schedule_work() after rtl8xxxu_stop() had set shutdown and cancel_work_sync() had already returned, arming the worker to run after the teardown. Move schedule_work() under the same !shutdown branch so the arming decision is atomic with the shutdown check. * rtl8xxxu_rx_urb_work() anchors every URB it drained back onto rx_anchor through rtl8xxxu_submit_rx_urb(). A worker still running when usb_kill_anchored_urbs(&priv->rx_anchor) returned would submit a URB that escaped the kill. In rtl8xxxu_stop(), call cancel_work_sync(&priv->rx_urb_wq) before the kill so the worker is drained first. After priv->shutdown is set under rx_urb_lock, completions can no longer queue rx_urb_wq. cancel_work_sync() then drains the last queued or running worker, and the following usb_kill_anchored_urbs() kills the URBs it may have submitted. rtl8xxxu_disconnect() is covered because ieee80211_unregister_hw() guarantees .stop() runs for a live interface before ieee80211_free_hw() frees priv. The probe error path needs no cancel: rx_urb_wq is INIT_WORK()'d there but cannot have been scheduled, since no URB is submitted before ieee80211_register_hw() succeeds. This bug was found by static analysis.

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

References

Track CVE-2026-80947 inside VULONE

Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.

Start free Open in platform

Source: NIST National Vulnerability Database (record CVE-2026-80947), CISA KEV, FIRST EPSS (scores of 2026-09-27). This page is refreshed as NVD updates the record.