CVE-2026-76280: Splunk incorrect permission assignment vulnerability
Splunk · Splunk
In Splunk Enterprise versions below 10.4.3, 10.2.7, 10.0.10, and 9.4.15, and Splunk Secure Gateway versions below 3.10.11, 3.9.25, and 3.8.72, an authenticated user who does not hold the "admin" or "sc_admin" Splunk roles could modify Splunk Secure Gateway alert and mobile-device recipient data in App Key Value Store (KV Store) collections that later alert and subscription workflows use. The vulnerability is possible because the affected collections allow unrestricted write access instead of limiting writes to authorized Splunk Secure Gateway workflows. For more information see About the app key value store (https://help.splunk.com/en/splunk-enterprise/administer/admin-manual/10.4/administer-the-app-key-value-store/about-the-app-key-value-store), KV store endpoint descriptions (https://help.splunk.com/en/splunk-enterprise/leverage-rest-apis/rest-api-reference/10.4/kv-store-endpoints/kv-store-endpoint-descriptions), and About configuring role-based user access (https://help.splunk.com/en/splunk-enterprise/administer/manage-users-and-security/10.4/manage-splunk-platform-users-and-roles/about-configuring-role-based-user-access) in the Splunk documentation.
Description
In Splunk Enterprise versions below 10.4.3, 10.2.7, 10.0.10, and 9.4.15, and Splunk Secure Gateway versions below 3.10.11, 3.9.25, and 3.8.72, an authenticated user who does not hold the "admin" or "sc_admin" Splunk roles could modify Splunk Secure Gateway alert and mobile-device recipient data in App Key Value Store (KV Store) collections that later alert and subscription workflows use. The vulnerability is possible because the affected collections allow unrestricted write access instead of limiting writes to authorized Splunk Secure Gateway workflows. For more information see About the app key value store (https://help.splunk.com/en/splunk-enterprise/administer/admin-manual/10.4/administer-the-app-key-value-store/about-the-app-key-value-store), KV store endpoint descriptions (https://help.splunk.com/en/splunk-enterprise/leverage-rest-apis/rest-api-reference/10.4/kv-store-endpoints/kv-store-endpoint-descriptions), and About configuring role-based user access (https://help.splunk.com/en/splunk-enterprise/administer/manage-users-and-security/10.4/manage-splunk-platform-users-and-roles/about-configuring-role-based-user-access) in the Splunk documentation.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Affected products
2 vulnerable configurations from NVD's CPE data, grouped by vendor and product.
References
| Link | Tags |
|---|---|
| https://advisory.splunk.com/advisories/SVD-2026-1001 | Vendor Advisory |
Track CVE-2026-76280 inside VULONE
Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.
Related vulnerabilities
Same products first, then exploited flaws of the same weakness class.
Source: NIST National Vulnerability Database (record CVE-2026-76280), CISA KEV, FIRST EPSS (scores of 2026-11-11). This page is refreshed as NVD updates the record.