← Vulnerability feed

Vulnerability record · CVE-2026-68472 · published 15 August 2026

CVE-2026-68472: In the Linux kernel, the following vulnerability has been resolved: wifi: cfg80211: validate EHT MLE before M…

In the Linux kernel, the following vulnerability has been resolved: wifi: cfg80211: validate EHT MLE before MLD ID read cfg80211_gen_new_ie() copies ML probe response elements from the parent frame when the parent EHT multi-link element has an MLD ID matching the nontransmitted BSSID index. The code only checked that the extension element had more than one byte before calling ieee80211_mle_get_mld_id(). That helper assumes a BASIC MLE with enough common info and documents that callers must first use ieee80211_mle_type_ok(). Attack chain: malicious AP sends a short EHT MLE in an MBSSID beacon. cfg80211_inform_bss_frame_data() stores the copied IE buffer. cfg80211_parse_mbssid_data() builds the nontransmitted BSS IE. cfg80211_gen_new_ie() sees the EHT MLE in the parent frame. ieee80211_mle_get_mld_id() then reads past the IE boundary. Validate the MLE type and size before reading the MLD ID. This matches the contract required by the MLE helper and rejects the short element before any internal MLE fields are accessed.

8.1 CVSS 3.1 High EPSS 0.34% · top 74.8% Received
8.1CVSS 3.1 base score
0.34%EPSS exploitation probability, 30 days
NoNot in CISA KEV
0Affected product versions listed by NVD
3References
17 Aug 2026Last modified by NVD

Description

In the Linux kernel, the following vulnerability has been resolved: wifi: cfg80211: validate EHT MLE before MLD ID read cfg80211_gen_new_ie() copies ML probe response elements from the parent frame when the parent EHT multi-link element has an MLD ID matching the nontransmitted BSSID index. The code only checked that the extension element had more than one byte before calling ieee80211_mle_get_mld_id(). That helper assumes a BASIC MLE with enough common info and documents that callers must first use ieee80211_mle_type_ok(). Attack chain: malicious AP sends a short EHT MLE in an MBSSID beacon. cfg80211_inform_bss_frame_data() stores the copied IE buffer. cfg80211_parse_mbssid_data() builds the nontransmitted BSS IE. cfg80211_gen_new_ie() sees the EHT MLE in the parent frame. ieee80211_mle_get_mld_id() then reads past the IE boundary. Validate the MLE type and size before reading the MLD ID. This matches the contract required by the MLE helper and rejects the short element before any internal MLE fields are accessed.

CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H

References

Track CVE-2026-68472 inside VULONE

Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.

Start free Open in platform

Source: NIST National Vulnerability Database (record CVE-2026-68472), CISA KEV, FIRST EPSS (scores of 2026-09-28). This page is refreshed as NVD updates the record.