Vulnerability record · CVE-2026-57025 · published 9 July 2026
CVE-2026-57025: Juniper junos vulnerability
Juniper · Junos
A Return of Pointer Value Outside of Expected Range vulnerability in the fileio library of Juniper Networks Junos OS and Junos OS Evolved allows a local, low-privilged attacker to cause a Denial-of-Service (DoS). On EX Series, QFX Series and MX Series a low-privileged attacker issuing a specific 'show l2-learning' or 'show ethernet-switching' command will cause an l2ald crash which will lead to a temporary service impact for all layer 2 services until the process has automatically restarted. This issue affects EX Series, QFX Series, MX Series: Junos OS: * all versions before 23.2R2-S7, * 23.4 versions before 23.4R2-S7, * 24.2 versions before 24.2R2, * 24.4 versions before 24.4R1-S2. Junos OS Evolved: * all versions before 23.2R2-S7-EVO, * 23.4 versions before 23.4R2-S8-EVO, * 24.2 versions before 24.2R2-EVO, * 24.4 versions before 24.4R1-S3-EVO.
Description
A Return of Pointer Value Outside of Expected Range vulnerability in the fileio library of Juniper Networks Junos OS and Junos OS Evolved allows a local, low-privilged attacker to cause a Denial-of-Service (DoS). On EX Series, QFX Series and MX Series a low-privileged attacker issuing a specific 'show l2-learning' or 'show ethernet-switching' command will cause an l2ald crash which will lead to a temporary service impact for all layer 2 services until the process has automatically restarted. This issue affects EX Series, QFX Series, MX Series: Junos OS: * all versions before 23.2R2-S7, * 23.4 versions before 23.4R2-S7, * 24.2 versions before 24.2R2, * 24.4 versions before 24.4R1-S2. Junos OS Evolved: * all versions before 23.2R2-S7-EVO, * 23.4 versions before 23.4R2-S8-EVO, * 24.2 versions before 24.2R2-EVO, * 24.4 versions before 24.4R1-S3-EVO.
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:
Affected products
2 vulnerable configurations from NVD's CPE data, grouped by vendor and product.
References
| Link | Tags |
|---|---|
| https://supportportal.juniper.net/JSA110085 | Vendor Advisory |
Track CVE-2026-57025 inside VULONE