Vulnerability record · CVE-2026-26985 · published 25 February 2026
CVE-2026-26985: Mcgill loris path traversal vulnerability
Mcgill · Loris
LORIS (Longitudinal Online Research and Imaging System) is a self-hosted web application that provides data- and project-management for neuroimaging research. Starting in version 24.0.0 and prior to versions 26.0.5, 27.0.2, and 28.0.0, an authenticated user with the appropriate authorization can read configuration files on the server by exploiting a path traversal vulnerability. Some of these files contain hard-coded credentials. The vulnerability allows an attacker to read configuration files containing hard-coded credentials. The attacker could then authenticate to the database or other services if those credentials are reused. The attacker must be authenticated and have the required permissions. However, the vulnerability is easy to exploit and the application source code is public. This problem is fixed in LORIS v26.0.5 and v27.0.2 and above, and v28.0.0 and above. As a workaround, the electrophysiogy_browser in LORIS can be disabled by an administrator using the module manager.
Description
LORIS (Longitudinal Online Research and Imaging System) is a self-hosted web application that provides data- and project-management for neuroimaging research. Starting in version 24.0.0 and prior to versions 26.0.5, 27.0.2, and 28.0.0, an authenticated user with the appropriate authorization can read configuration files on the server by exploiting a path traversal vulnerability. Some of these files contain hard-coded credentials. The vulnerability allows an attacker to read configuration files containing hard-coded credentials. The attacker could then authenticate to the database or other services if those credentials are reused. The attacker must be authenticated and have the required permissions. However, the vulnerability is easy to exploit and the application source code is public. This problem is fixed in LORIS v26.0.5 and v27.0.2 and above, and v28.0.0 and above. As a workaround, the electrophysiogy_browser in LORIS can be disabled by an administrator using the module manager.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Affected products
1 vulnerable configurations from NVD's CPE data, grouped by vendor and product.
References
| Link | Tags |
|---|---|
| https://github.com/aces/Loris/releases/tag/v26.0.5 | ProductRelease Notes |
| https://github.com/aces/Loris/releases/tag/v27.0.2 | ProductRelease Notes |
| https://github.com/aces/Loris/security/advisories/GHSA-g3pp-rqvq-xxhp | Vendor Advisory |
Track CVE-2026-26985 inside VULONE
Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.
Related vulnerabilities
Same products first, then exploited flaws of the same weakness class.
Source: NIST National Vulnerability Database (record CVE-2026-26985), CISA KEV, FIRST EPSS (scores of 2026-09-26). This page is refreshed as NVD updates the record.