Vulnerability record · CVE-2026-100639 · published 26 September 2026
CVE-2026-100639: Cross-site scripting vulnerability
SiYuan v3.8.3 fails to HTML-escape the data-subtype attribute when generating gutter-button markup (app/src/protyle/gutter/button.ts, assigned via innerHTML in app/src/protyle/gutter/index.ts) from content pasted as plain-text Markdown containing a Kramdown inline attribute list (IAL). Because the shared Lute renderer parses Kramdown IAL from text/plain input, an attacker-supplied Markdown snippet using entity-encoded quotes in data-subtype breaks out of the attribute value when the gutter markup is re-parsed by the browser, injecting additional attributes such as autofocus and onfocus. If a victim pastes the crafted Markdown and the affected gutter control receives focus, the injected handler executes; in the Electron desktop application, where the main BrowserWindow enables Node integration and disables context isolation, this results in JavaScript execution with renderer Node.js privileges (remote code execution). Fixed in v3.8.4.
Description
SiYuan v3.8.3 fails to HTML-escape the data-subtype attribute when generating gutter-button markup (app/src/protyle/gutter/button.ts, assigned via innerHTML in app/src/protyle/gutter/index.ts) from content pasted as plain-text Markdown containing a Kramdown inline attribute list (IAL). Because the shared Lute renderer parses Kramdown IAL from text/plain input, an attacker-supplied Markdown snippet using entity-encoded quotes in data-subtype breaks out of the attribute value when the gutter markup is re-parsed by the browser, injecting additional attributes such as autofocus and onfocus. If a victim pastes the crafted Markdown and the affected gutter control receives focus, the injected handler executes; in the Electron desktop application, where the main BrowserWindow enables Node integration and disables context isolation, this results in JavaScript execution with renderer Node.js privileges (remote code execution). Fixed in v3.8.4.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:
References
Track CVE-2026-100639 inside VULONE
Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.
Related vulnerabilities
Same products first, then exploited flaws of the same weakness class.
Source: NIST National Vulnerability Database (record CVE-2026-100639), CISA KEV, FIRST EPSS. This page is refreshed as NVD updates the record.