← Vulnerability feed

Vulnerability record · CVE-2025-70161 · published 9 January 2026

CVE-2025-70161: Edimax br-6208ac firmware command injection vulnerability

Edimax · Br 6208ac Firmware

EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection. This arises because the pppUserName field is directly passed to a shell command via the system() function without proper sanitization. An attacker can exploit this by injecting malicious commands into the pppUserName field, allowing arbitrary code execution.

9.8 CVSS 3.1 Critical EPSS 27% · top 2.0% CWE-77 · Command injection
9.8CVSS 3.1 base score
27%EPSS exploitation probability, 30 days
NoNot in CISA KEV
1Affected product versions listed by NVD
1References, 1 tagged exploit
17 Jun 2026Last modified by NVD

Description

EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection. This arises because the pppUserName field is directly passed to a shell command via the system() function without proper sanitization. An attacker can exploit this by injecting malicious commands into the pppUserName field, allowing arbitrary code execution.

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected products

1 vulnerable configurations from NVD's CPE data, grouped by vendor and product.

References

Track CVE-2025-70161 inside VULONE

Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.

Start free Open in platform

Related vulnerabilities

Same products first, then exploited flaws of the same weakness class.

5.5CVE-2026-1972Edimax br-6208ac firmware vulnerabilityA vulnerability was found in Edimax BR-6208AC 2_1.02. The affected element is the function auth_check_userpass2. Performing a manipulation of the arg…EPSS 0.64%5.5CVE-2025-15257Edimax br-6208ac firmware injection vulnerabilityA security flaw has been discovered in Edimax BR-6208AC 1.02/1.03. Affected by this vulnerability is the function formRoute of the file /gogorm/formR…EPSS 5.1%5.5CVE-2025-15256Edimax br-6208ac firmware injection vulnerabilityA vulnerability was identified in Edimax BR-6208AC 1.02/1.03. Affected is the function formStaDrvSetup of the file /goform/formStaDrvSetup of the com…EPSS 3.8%2.1CVE-2025-14910Edimax br-6208ac firmware path traversal vulnerabilityA vulnerability was detected in Edimax BR-6208AC 1.02. This impacts the function handle_retr of the component FTP Daemon Service. The manipulation re…EPSS 0.53%2.0CVE-2025-15258Edimax br-6208ac firmware open redirect vulnerabilityA weakness has been identified in Edimax BR-6208AC 1.02/1.03. Affected by this issue is the function formALGSetup of the file /goform/formALGSetup of…EPSS 0.26%9.8CVE-2026-8037Progress LoadMaster API OS Command Injection RCEProgress LoadMaster (and related ADC products) contain an OS command injection flaw in multiple API command endpoints where unsanitized input is pass…KEVEPSS 77%analysed8.7CVE-2026-42271LiteLLM MCP test endpoints allow authenticated OS command injectionLiteLLM versions 1.74.2 through before 1.83.7 expose two MCP preview endpoints (POST /mcp-rest/test/connection and POST /mcp-rest/test/tools/list) th…KEVEPSS 13%analysed7.2CVE-2025-29635D-Link DIR-823X command injection in set_prohibiting handlerD-Link DIR-823X firmware (240126 and 240802) contains a command injection flaw in the /goform/set_prohibiting POST handler. An attacker who already h…KEVEPSS 88%analysed

Source: NIST National Vulnerability Database (record CVE-2025-70161), CISA KEV, FIRST EPSS (scores of 2026-09-26). This page is refreshed as NVD updates the record.