Vulnerability record · CVE-2025-68623 · published 11 March 2026
CVE-2025-68623: Improper access control vulnerability
In Microsoft DirectX End-User Runtime Web Installer 9.29.1974.0, a low-privilege user can replace an executable file during the installation process, which may result in unintended elevation of privileges. During installation, the installer runs with HIGH integrity and downloads executables and DLLs to the %TEMP% folder - writable by standard users. Subsequently, the installer executes the downloaded executable with HIGH integrity to complete the application installation. However, an attacker can replace the downloaded executable with a malicious, user-controlled executable. When the installer executes this replaced file, it runs the attacker's code with HIGH integrity. Since code running at HIGH integrity can escalate to SYSTEM level by registering and executing a service, this creates a complete privilege escalation chain from standard user to SYSTEM. NOTE: The Supplier disputes this record stating that they have determined this to be the behavior as designed.
Description
In Microsoft DirectX End-User Runtime Web Installer 9.29.1974.0, a low-privilege user can replace an executable file during the installation process, which may result in unintended elevation of privileges. During installation, the installer runs with HIGH integrity and downloads executables and DLLs to the %TEMP% folder - writable by standard users. Subsequently, the installer executes the downloaded executable with HIGH integrity to complete the application installation. However, an attacker can replace the downloaded executable with a malicious, user-controlled executable. When the installer executes this replaced file, it runs the attacker's code with HIGH integrity. Since code running at HIGH integrity can escalate to SYSTEM level by registering and executing a service, this creates a complete privilege escalation chain from standard user to SYSTEM. NOTE: The Supplier disputes this record stating that they have determined this to be the behavior as designed.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
References
Track CVE-2025-68623 inside VULONE
Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.
Related vulnerabilities
Same products first, then exploited flaws of the same weakness class.
Source: NIST National Vulnerability Database (record CVE-2025-68623), CISA KEV, FIRST EPSS (scores of 2026-09-26). This page is refreshed as NVD updates the record.