Vulnerability record · CVE-2022-35927 · published 4 August 2022
CVE-2022-35927: Contiki-ng classic buffer overflow vulnerability
Contiki Ng · Contiki Ng
Contiki-NG is an open-source, cross-platform operating system for IoT devices. In the RPL-Classic routing protocol implementation in the Contiki-NG operating system, an incoming DODAG Information Option (DIO) control message can contain a prefix information option with a length parameter. The value of the length parameter is not validated, however, and it is possible to cause a buffer overflow when copying the prefix in the set_ip_from_prefix function. This vulnerability affects anyone running a Contiki-NG version prior to 4.7 that can receive RPL DIO messages from external parties. To obtain a patched version, users should upgrade to Contiki-NG 4.7 or later. There are no workarounds for this issue.
Description
Contiki-NG is an open-source, cross-platform operating system for IoT devices. In the RPL-Classic routing protocol implementation in the Contiki-NG operating system, an incoming DODAG Information Option (DIO) control message can contain a prefix information option with a length parameter. The value of the length parameter is not validated, however, and it is possible to cause a buffer overflow when copying the prefix in the set_ip_from_prefix function. This vulnerability affects anyone running a Contiki-NG version prior to 4.7 that can receive RPL DIO messages from external parties. To obtain a patched version, users should upgrade to Contiki-NG 4.7 or later. There are no workarounds for this issue.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Affected products
1 vulnerable configurations from NVD's CPE data, grouped by vendor and product.
References
| Link | Tags |
|---|---|
| https://github.com/contiki-ng/contiki-ng/pull/1589 | Third Party Advisory |
| https://github.com/contiki-ng/contiki-ng/pull/1589/commits/4fffab0e632c4d01910fa957d1fd9ef321eb87d2 | PatchThird Party Advisory |
| https://github.com/contiki-ng/contiki-ng/security/advisories/GHSA-9rm9-3phh-p4wm | Third Party Advisory |
| https://github.com/contiki-ng/contiki-ng/pull/1589 | Third Party Advisory |
| https://github.com/contiki-ng/contiki-ng/pull/1589/commits/4fffab0e632c4d01910fa957d1fd9ef321eb87d2 | PatchThird Party Advisory |
| https://github.com/contiki-ng/contiki-ng/security/advisories/GHSA-9rm9-3phh-p4wm | Third Party Advisory |