CVE-2022-24314: Schneider-electric interactive graphical scada system data server out-of-bounds read vulnerability

Schneider Electric · Interactive Graphical Scada System Data Server

A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

7.5 CVSS 3.1 High EPSS 18% · top 2.9% CWE-125 · Out-of-bounds read
7.5CVSS 3.1 base score, v2 5.0
18%EPSS exploitation probability, 30 days
NoNot in CISA KEV
1Affected product versions listed by NVD
2References
17 Jun 2026Last modified by NVD

Description

A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Affected products

1 vulnerable configurations from NVD's CPE data, grouped by vendor and product.

References

Track CVE-2022-24314 inside VULONE

Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.

Start free Open in platform

Related vulnerabilities

Same products first, then exploited flaws of the same weakness class.

9.8CVE-2022-24310Schneider-electric interactive graphical scada system data server integer overflow vulnerabilityA CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentia…EPSS 2.2%9.8CVE-2022-24311Schneider-electric interactive graphical scada system data server path traversal vulnerabilityA CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inser…EPSS 3.5%9.8CVE-2022-24312Schneider-electric interactive graphical scada system data server path traversal vulnerabilityA CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by addin…EPSS 3.5%9.8CVE-2022-24313Schneider-electric interactive graphical scada system data server classic buffer overflow vulnerabilityA CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remo…EPSS 45%7.5CVE-2022-24315Schneider-electric interactive graphical scada system data server out-of-bounds read vulnerabilityA CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. …EPSS 19%7.5CVE-2022-24316Schneider-electric interactive graphical scada system data server vulnerabilityA CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Aff…EPSS 1.3%7.5CVE-2022-24317Schneider-electric interactive graphical scada system data server missing authorization vulnerabilityA CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Produ…EPSS 1.2%8.8CVE-2026-11645Google Chrome V8 out-of-bounds read and write enables sandbox code executionGoogle Chrome before 149.0.7827.103 contains an out-of-bounds read and write in the V8 JavaScript engine. A crafted HTML page can trigger the memory …KEVEPSS 2.2%analysed

Source: NIST National Vulnerability Database (record CVE-2022-24314), CISA KEV, FIRST EPSS (scores of 2026-09-26). This page is refreshed as NVD updates the record.