← Vulnerability feed

Vulnerability record · CVE-2021-37162 · published 2 August 2021

CVE-2021-37162: Swisslog-healthcare hmi-3 control panel firmware classic buffer overflow vulnerability

Swisslog Healthcare · Hmi 3 Control Panel Firmware

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote code execution.

9.8 CVSS 3.1 Critical EPSS 3.3% · top 12.1% CWE-120 · Classic buffer overflow
9.8CVSS 3.1 base score, v2 7.5
3.3%EPSS exploitation probability, 30 days
NoNot in CISA KEV
1Affected product versions listed by NVD
8References
17 Jun 2026Last modified by NVD

Description

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote code execution.

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected products

1 vulnerable configurations from NVD's CPE data, grouped by vendor and product.

References

Track CVE-2021-37162 inside VULONE

Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.

Start free Open in platform

Related vulnerabilities

Same products first, then exploited flaws of the same weakness class.

9.8CVE-2021-37160Swisslog-healthcare hmi-3 control panel firmware improper verification of cryptographic signature vulnerabilityA firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before …EPSS 8.2%9.8CVE-2021-37161Swisslog-healthcare hmi-3 control panel firmware classic buffer overflow vulnerabilityA buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions …EPSS 3.3%9.8CVE-2021-37163Swisslog-healthcare hmi-3 control panel firmware hard-coded credentials vulnerabilityAn insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexu…EPSS 1.4%9.8CVE-2021-37164Swisslog-healthcare hmi-3 control panel firmware out-of-bounds write vulnerabilityA buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexu…EPSS 3.4%9.8CVE-2021-37167Swisslog-healthcare hmi-3 control panel firmware improper privilege management vulnerabilityAn insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software befor…EPSS 1.7%9.8CVE-2021-37165Swisslog-healthcare hmi-3 control panel firmware classic buffer overflow vulnerabilityA buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexu…EPSS 3.3%7.5CVE-2021-37166Swisslog-healthcare hmi-3 control panel firmware classic buffer overflow vulnerabilityA buffer overflow issue leading to denial of service was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released ver…EPSS 2.1%5.5CVE-2025-43520Apple OS kernel memory corruption via malicious appA memory corruption flaw (classic buffer overflow) in Apple's kernel was fixed across iOS, iPadOS, macOS, tvOS, visionOS and watchOS. A malicious app…KEVEPSS 0.43%analysed