← Vulnerability feed

Vulnerability record · CVE-2021-25660 · published 12 May 2021

CVE-2021-25660: Siemens simatic hmi comfort outdoor panels 7\" firmware memory buffer overflow vulnerability

Siemens · Simatic Hmi Comfort Outdoor Panels 7\" Firmware

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.

7.5 CVSS 3.1 High EPSS 0.97% · top 39.6% CWE-788 · CWE-788CWE-119 · Memory buffer overflow
7.5CVSS 3.1 base score, v2 5.0
0.97%EPSS exploitation probability, 30 days
NoNot in CISA KEV
10Affected product versions listed by NVD
2References
17 Jun 2026Last modified by NVD

Description

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Affected products

10 vulnerable configurations from NVD's CPE data, grouped by vendor and product.

References

Track CVE-2021-25660 inside VULONE

Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.

Start free Open in platform

Related vulnerabilities

Same products first, then exploited flaws of the same weakness class.

9.8CVE-2021-27384Siemens simatic wincc runtime advanced vulnerabilityA vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIM…EPSS 2.6%9.1CVE-2019-6572Siemens simatic hmi comfort panels firmware information exposure vulnerabilityA vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 1…EPSS 2.7%8.8CVE-2018-13814Siemens simatic hmi comfort panels firmware improper input validation vulnerabilityA vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All ver…EPSS 1.7%8.1CVE-2018-13813Siemens simatic hmi comfort panels firmware open redirect vulnerabilityA vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15"…EPSS 1.7%7.5CVE-2021-25661Siemens simatic wincc runtime advanced vulnerabilityA vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIM…EPSS 1.1%7.5CVE-2021-25662Siemens simatic wincc runtime advanced vulnerabilityA vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIM…EPSS 1.6%7.5CVE-2021-27383Siemens simatic wincc runtime advanced allocation without limits vulnerabilityA vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIM…EPSS 1.8%7.5CVE-2021-27385Siemens simatic wincc runtime advanced uncontrolled resource consumption vulnerabilityA vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIM…EPSS 2.6%

Source: NIST National Vulnerability Database (record CVE-2021-25660), CISA KEV, FIRST EPSS (scores of 2026-09-27). This page is refreshed as NVD updates the record.