← Vulnerability feed

Vulnerability record · CVE-2020-7536 · published 11 December 2020

CVE-2020-7536: Schneider-electric modicon m340 bmxp341000 firmware vulnerability

Schneider Electric · Modicon M340 Bmxp341000 Firmware

A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs (BMXP34* versions prior to V3.30) Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.4 BMXNOE0110 (H) versions prior to V6.6 BMXNOR0200H all versions), that could cause the device to be unreachable when modifying network parameters over SNMP.

7.5 CVSS 3.1 High EPSS 1.2% · top 33.5% CWE-754 · CWE-754
7.5CVSS 3.1 base score, v2 7.8
1.2%EPSS exploitation probability, 30 days
NoNot in CISA KEV
10Affected product versions listed by NVD
4References
17 Jun 2026Last modified by NVD

Description

A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs (BMXP34* versions prior to V3.30) Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.4 BMXNOE0110 (H) versions prior to V6.6 BMXNOR0200H all versions), that could cause the device to be unreachable when modifying network parameters over SNMP.

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Affected products

10 vulnerable configurations from NVD's CPE data, grouped by vendor and product.

References

Track CVE-2020-7536 inside VULONE

Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.

Start free Open in platform

Related vulnerabilities

Same products first, then exploited flaws of the same weakness class.

9.8CVE-2022-45789Schneider-electric ecostruxure control expert authentication bypass by capture-replay vulnerabilityA CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller…EPSS 1.5%9.8CVE-2022-45788Schneider-electric ecostruxure control expert vulnerabilityA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and…EPSS 1.2%9.8CVE-2022-37300Schneider-electric ecostruxure control expert weak password recovery vulnerabilityA CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode t…EPSS 0.77%9.8CVE-2020-7540Schneider-electric modicon m340 bmxp341000 firmware missing authentication for critical function vulnerabilityA CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Mod…EPSS 2.3%9.8CVE-2020-7533Schneider-electric modicon m340 bmxp3420302 firmware improper authentication vulnerabilityCWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sendin…EPSS 2.3%9.8CVE-2018-7761Schneider-electric bmxnor0200 firmware improper input validation vulnerabilityA vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could …EPSS 2.1%9.8CVE-2018-7241Schneider-electric bmxnor0200 firmware hard-coded credentials vulnerabilityHard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the c…EPSS 3.7%9.8CVE-2018-7760Schneider-electric bmxnor0200 firmware improper authentication vulnerabilityAn authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI …EPSS 1.5%

Source: NIST National Vulnerability Database (record CVE-2020-7536), CISA KEV, FIRST EPSS (scores of 2026-10-10). This page is refreshed as NVD updates the record.