← Vulnerability feed

Vulnerability record · CVE-2019-19276 · published 12 May 2021

CVE-2019-19276: Siemens simatic hmi ktp mobile panels firmware out-of-bounds write vulnerability

Siemens · Simatic Hmi Ktp Mobile Panels Firmware

A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service.

5.3 CVSS 3.1 Medium EPSS 1.0% · top 37.8% CWE-787 · Out-of-bounds write
5.3CVSS 3.1 base score, v2 5.0
1.0%EPSS exploitation probability, 30 days
NoNot in CISA KEV
2Affected product versions listed by NVD
2References
17 Jun 2026Last modified by NVD

Description

A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service.

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L

Affected products

2 vulnerable configurations from NVD's CPE data, grouped by vendor and product.

References

Track CVE-2019-19276 inside VULONE

Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.

Start free Open in platform

Related vulnerabilities

Same products first, then exploited flaws of the same weakness class.

9.8CVE-2020-15798Siemens simatic hmi comfort panels firmware missing authentication for critical function vulnerabilityA vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Pane…EPSS 5.2%9.8CVE-2020-15786Siemens simatic hmi basic panels 2nd generation firmware improper restriction of authentication attempts vulnerabilityA vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Pane…EPSS 1.5%9.1CVE-2019-6572Siemens simatic hmi comfort panels firmware information exposure vulnerabilityA vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 1…EPSS 2.7%8.8CVE-2018-13814Siemens simatic hmi comfort panels firmware improper input validation vulnerabilityA vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All ver…EPSS 1.7%8.1CVE-2018-13813Siemens simatic hmi comfort panels firmware open redirect vulnerabilityA vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15"…EPSS 1.7%7.5CVE-2022-40227Siemens simatic hmi comfort panels firmware improper input validation vulnerabilityA vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V17 Update 4), SIMATIC HMI KTP Mobile Panel…EPSS 0.84%7.5CVE-2019-10936Siemens dk standard ethernet controller firmware uncontrolled resource consumption vulnerabilityAffected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a d…EPSS 2.1%7.5CVE-2019-6568Siemens cp1604 firmware out-of-bounds read vulnerabilityThe webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of serv…EPSS 1.4%

Source: NIST National Vulnerability Database (record CVE-2019-19276), CISA KEV, FIRST EPSS (scores of 2026-10-05). This page is refreshed as NVD updates the record.