← Vulnerability feed

Vulnerability record · CVE-2017-9538 · published 3 October 2017

CVE-2017-9538: Solarwinds network performance monitor improper input validation vulnerability

Solarwinds · Network Performance Monitor

The 'Upload logo from external path' function of SolarWinds Network Performance Monitor version 12.0.15300.90 allows remote attackers to cause a denial of service (permanent display of a "Cannot exit above the top directory" error message throughout the entire web application) via a ".." in the path field. In other words, the denial of service is caused by an incorrect implementation of a directory-traversal protection mechanism.

4.9 CVSS 3.0 Medium EPSS 2.4% · top 16.4% CWE-20 · Improper input validation
4.9CVSS 3.0 base score, v2 4.0
2.4%EPSS exploitation probability, 30 days
NoNot in CISA KEV
1Affected product versions listed by NVD
4References
17 Jun 2026Last modified by NVD

Description

The 'Upload logo from external path' function of SolarWinds Network Performance Monitor version 12.0.15300.90 allows remote attackers to cause a denial of service (permanent display of a "Cannot exit above the top directory" error message throughout the entire web application) via a ".." in the path field. In other words, the denial of service is caused by an incorrect implementation of a directory-traversal protection mechanism.

CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H

Affected products

1 vulnerable configurations from NVD's CPE data, grouped by vendor and product.

References

Track CVE-2017-9538 inside VULONE

Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.

Start free Open in platform

Related vulnerabilities

Same products first, then exploited flaws of the same weakness class.

9.8CVE-2021-31474SolarWinds Network Performance Monitor unauthenticated deserialization RCESolarWinds Network Performance Monitor 2020.2.1 contains a deserialization of untrusted data flaw in the SolarWinds.Serialization library, caused by …EPSS 94%analysed8.8CVE-2020-27869Solarwinds network performance monitor sql injection vulnerabilityThis vulnerability allows remote attackers to escalate privileges on affected installations of SolarWinds Network Performance Monitor 2020 HF1, NPM: …EPSS 5.3%8.8CVE-2018-13442Solarwinds network performance monitor sql injection vulnerabilitySolarWinds Network Performance Monitor 12.3 allows SQL Injection via the /api/ActiveAlertsOnThisEntity/GetActiveAlerts TriggeringObjectEntityNames pa…EPSS 1.7%6.4CVE-2021-35225Solarwinds network performance monitor vulnerabilityEach authenticated Orion Platform user in a MSP (Managed Service Provider) environment can view and browse all NetPath Services from all that MSP's c…EPSS 0.84%5.5CVE-2019-12864Solarwinds netpath error message information leak vulnerabilitySolarWinds Orion Platform 2018.4 HF3 (NPM 12.4, NetPath 1.1.4) is vulnerable to Information Leakage, because of improper error handling with stack tr…EPSS 0.47%4.8CVE-2019-12863Solarwinds netpath cross-site scripting vulnerabilitySolarWinds Orion Platform 2018.4 HF3 (NPM 12.4, NetPath 1.1.4) allows Stored HTML Injection by administrators via the Web Console Settings screen.EPSS 1.1%4.8CVE-2017-9537Solarwinds network performance monitor cross-site scripting vulnerabilityPersistent cross-site scripting (XSS) in the Add Node function of SolarWinds Network Performance Monitor version 12.0.15300.90 allows remote attacker…EPSS 2.8%9.5CVE-2026-88771Citrix netscaler application delivery controller improper input validation vulnerabilityImproper input validation vulnerability in Citrix NetScaler ADC and Citrix NetScaler Gateway. This issue affects ADC: before 14.1-73.37, before 13.1-…KEV

Source: NIST National Vulnerability Database (record CVE-2017-9538), CISA KEV, FIRST EPSS (scores of 2026-09-27). This page is refreshed as NVD updates the record.