← Vulnerability feed

Vulnerability record · CVE-2017-7899 · published 30 June 2017

CVE-2017-7899: Rockwellautomation 1763-l16awa series a information exposure vulnerability

Rockwellautomation · 1763 L16awa Series A

An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. User credentials are sent to the web server using the HTTP GET method, which may result in the credentials being logged. This could make user credentials available for unauthorized retrieval.

9.8 CVSS 3.0 Critical EPSS 4.7% · top 8.6% CWE-200 · Information exposure
9.8CVSS 3.0 base score, v2 5.0
4.7%EPSS exploitation probability, 30 days
NoNot in CISA KEV
20Affected product versions listed by NVD
4References
17 Jun 2026Last modified by NVD

Description

An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. User credentials are sent to the web server using the HTTP GET method, which may result in the credentials being logged. This could make user credentials available for unauthorized retrieval.

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected products

20 vulnerable configurations from NVD's CPE data, grouped by vendor and product.

References

Track CVE-2017-7899 inside VULONE

Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.

Start free Open in platform

Related vulnerabilities

Same products first, then exploited flaws of the same weakness class.

9.8CVE-2017-7898Rockwellautomation 1763-l16awa series a improper restriction of authentication attempts vulnerabilityAn Improper Restriction of Excessive Authentication Attempts issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-l…EPSS 5.2%9.8CVE-2017-7902Rockwellautomation 1763-l16awa series a vulnerabilityA "Reusing a Nonce, Key Pair in Encryption" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers …EPSS 2.6%9.8CVE-2017-7903Rockwellautomation 1763-l16awa series a weak password requirements vulnerabilityA Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Se…EPSS 2.8%9.8CVE-2016-0868Rockwellautomation 1763-l16awa series a memory buffer overflow vulnerabilityStack-based buffer overflow on Rockwell Automation Allen-Bradley MicroLogix 1100 devices A through 15.000 and B before 15.002 allows remote attackers…EPSS 8.9%8.6CVE-2017-7901Rockwellautomation 1763-l16awa series a vulnerabilityA Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controlle…EPSS 6.7%7.3CVE-2016-9334Rockwellautomation 1763-l16awa series a vulnerabilityAn issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior version…EPSS 4.1%2.7CVE-2016-9338Rockwellautomation 1763-l16awa series a vulnerabilityAn issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior version…EPSS 2.4%5.9CVE-2025-68686FortiOS symbolic link patch bypass exposes sensitive informationFortiOS contains an information exposure flaw (CWE-200) that lets a remote unauthenticated attacker bypass the patch for the symbolic link persistenc…KEVEPSS 30%analysed

Source: NIST National Vulnerability Database (record CVE-2017-7899), CISA KEV, FIRST EPSS (scores of 2026-09-29). This page is refreshed as NVD updates the record.