← Vulnerability feed

Vulnerability record · CVE-2015-7918 · published 15 December 2015

CVE-2015-7918: Schneider-electric proclima memory buffer overflow vulnerability

Schneider Electric · Proclima

Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561.

6.8 CVSS 2.0 Medium EPSS 5.7% · top 7.2% CWE-119 · Memory buffer overflow
6.8CVSS 2.0 base score
5.7%EPSS exploitation probability, 30 days
NoNot in CISA KEV
1Affected product versions listed by NVD
18References
17 Jun 2026Last modified by NVD

Description

Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561.

AV:N/AC:M/Au:N/C:P/I:P/A:P

Affected products

1 vulnerable configurations from NVD's CPE data, grouped by vendor and product.

References

Track CVE-2015-7918 inside VULONE

Watch it alongside the ransomware crews, C2 infrastructure and forum chatter that reference it, query it through the API and pull it into your SIEM over TAXII.

Start free Open in platform

Related vulnerabilities

Same products first, then exploited flaws of the same weakness class.

10.0CVE-2014-8511Schneider-electric proclima memory buffer overflow vulnerabilityBuffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via …EPSS 4.4%9.8CVE-2019-6823Schneider-electric proclima code injection vulnerabilityA CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker…EPSS 5.0%9.8CVE-2019-6824Schneider-electric proclima memory buffer overflow vulnerabilityA CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to e…EPSS 4.5%7.8CVE-2019-6825Schneider-electric proclima uncontrolled search path element vulnerabilityA CWE-427: Uncontrolled Search Path Element vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow a malicious DLL …EPSS 1.2%6.8CVE-2015-8561Schneider-electric proclima memory buffer overflow vulnerabilityThe F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a …EPSS 3.8%9.5CVE-2026-88772Citrix NetScaler Improper Restriction of Operations within the Bounds of a Memory Buffer VulnerabilityVulnerability in Citrix NetScaler ADC and Citrix NetScaler Gateway. This issue affects ADC: before 14.1-73.37, before 13.1-64.23, before 14.1-73.37 F…KEV8.8CVE-2026-8452Citrix NetScaler ADC and Gateway memory buffer overflow causes DoSCVE-2026-8452 is a memory buffer overflow (CWE-119) in Citrix NetScaler ADC and NetScaler Gateway that leads to unpredictable or erroneous behavior a…KEVEPSS 1.0%analysed8.8CVE-2009-3459Adobe Reader and Acrobat heap buffer overflow via crafted PDFAdobe Reader and Acrobat 7.x before 7.1.4, 8.x before 8.1.7, and 9.x before 9.2 contain a heap-based buffer overflow (CWE-122) triggered by a crafted…KEVEPSS 87%analysed

Source: NIST National Vulnerability Database (record CVE-2015-7918), CISA KEV, FIRST EPSS (scores of 2026-09-27). This page is refreshed as NVD updates the record.